$5,070.00

SQ120BRDSBPR



Minimum/Maximum (gpm)30/70


































































































60 Hz SQ120R
BTUs
(water temp/ambient air/relative humidity)
80/80/80 110,000
80/80/63 103,000
80/50/63 72,000
Coefficient of Performance
(water temp/ambient air/relative humidity)
80/80/80 5.5
80/80/63 5.3
80/50/63 4.0
Refrigerant R410A
Electrical
Heat or Heat & Cool H & C
kW Input 5.9
Voltage/Hz/Phase
A – 208-230/60/1
B – 200-230/60/3
E – 380-415/60/3
G – 460/60/3
A & B
Minimum/Maximum Fuse Size A – 60
B – 50
Minimum Circuit Ampacity A – 38.5
B – 31.0
Water Flow
*A Heater Bypass Kit is required when flow rates exceed the maximum
Physical
Weight (lbs) 268
Size (lengthxwidthxheight) 34″ x 34″ x 44″
Shipping
Weight (lbs) 329
Size (lengthxwidthxheight) 38″ x 36″ x 49″


Rated in accordance with ARI standard 1160 water temp/ambient air/relative humidity